Showing Chassis and Component Status (asg monitor)
If you run asg stat -v, the output shows a higher unit weight and Chassis Grade:
Failure of an SGM with this high unit weight will cause a chassis failover, as the minimum grade
gap for chassis failover remained at 11.
Minimum threshold for traffic processing
The minimum grade required for the chassis to become ACTIVE.
Minimum grade gap for chassis failover
Minimum grade gap is a value that determines when a chassis fails over. If the active chassis grade
drops by the "minimum grade gap" failover may occur. The active chassis is always the chassis whose
grade is higher by at least the minimum grade gap.
Synchronization
Within chassis
Whether synchronization is enabled between SGMs in the same
chassis
Between chassis
Whether synchronization is enabled between SGMs in different chassis
Exception Rules
Whether the user has configured any synchronization exception rules
using the asg_sync_manager commands
Distribution
Control blade
Whether the control blade feature is enabled. The control blade feature
sets the SMO not to handle data traffic, only management traffic. When
the feature is enabled, you always have immediate access to the
system through an SSH connection.
Showing Chassis and Component Status
(asg monitor)
Description
Use this command to show the chassis and component state for single chassis
and dual chassis configurations.
Syntax
asg monitor [interval][-v [interval]][-all interval]