Vista de pagina 28
Performing the Initial Setup
4. Define the SGMs that belong to the Security Group.
There are two lines, one for Chassis 1, one for chassis 2. In each line, you can enter:
all (same as 1-12)
A range, such as: 1-9
A number of comma-separated ranges, such as: 1-3,5-7
Single SGMS, such as: 1,4
A combination of single SGMs and ranges, such as: 10,2, 3-7.
By default, the SGM you are connected belongs to the group: Chassis 1, SGM 1 (slot 1 in chassis
1). To define a fully populated dual chassis system select all in the top and bottom lines. For more
about Security Gateway Module numbering, see 61000 Security System front panel components
("61000 Security System Front Panel Modules" on page 9).
5. The subnet for internal communication in the chassis is 192.0.2.0/24 by default. Change the IP address
if it conflicts with an existing subnet on your network.
6. Configure parameters for:
Host Name
Time and Date.
To configure the local time, choose the geographical area and city.
7. Select Network Connections.
Configure the management ports and the data ports of the Security Switch Module.
There are 4 management ports on each SSM. Only configure those ports you intend to use. To
associate port names with the physical ports, refer to Security Switch Module Ports (on page 11).
For each management port configure:
An IP address
The Netmask length
To associate data port names with the physical ports, refer to Security Switch Module Ports (on
page 11). For each data port configure:
An IP address
The Netmask length
8. Configure Routing.
Note - Wait 10-20 seconds for routing information to be updated throughout the
system.
9. The Welcome to Check Point Suite screen shows. Wait for Check Point products packages to install,
such as Performance Pack.
10. Wait for the:
Installation Program Completed Successfully message to show
Check Point Configuration Program to start.
This program guides you through the configuration of Check Point products.
11. Configure Secure Internal Communication.
When prompted, enter and confirm the activation key. Remember this activation key. The same
activation key is used for configuring the 61000 Security System object in SmartDashboard.
Configuration settings are applied, and the SGM reboots. The other Security Gateway Modules in the
security group install automatically.